Cincinnati Test Systems Sentinel I28 Connector
Cincinnati Test Systems Sentinel I28 devices
- Name: Cincinnati
- Version: 1.1.0.0
- Protocol: Proprietary
- Interface: Serial
- Runtime: .NET 2.0 (Multiplatform)
- Configuration:
- Devices / Protocols
On This Page:
Overview
Communication Driver Information | |
|---|---|
Driver name | Cincinnati |
Assembly Name | T.ProtocolDriver.Cincinnati |
Assembly Version | 1.1.0.0 |
Available for Linux | False |
Devices supported | Devices compatible with Sentinel I-28 precision leak test instrument. |
Manufacturer | Cincinnati Test Systems |
Protocol | Proprietary |
Interface | RS232 or RS485 |
PC Requirements | Serial port |
Points Configuration
Address
The syntax for the Cincinnati communication point is: <Command>
- <Command>: It indicates that this specific command is associated with the specific Tag Name.
Command | Description |
P01Time | Time of Test #1 |
P01Date | Date of Test #1 |
P01Leak | Leak of Test #1 |
P01Loss | Loss of Test #1 |
P02Time | Time of Test #2 |
P02Date | Date of Test #2 |
P02Leak | Leak of Test #2 |
P02Loss | Loss of Test #2 |
P03Time | Time of Test #3 |
P03Date | Date of Test #3 |
P03Leak | Leak of Test #3 |
P03Loss | Loss of Test #3 |